SpectraMax Paradigm Multi-Mode Microplate Reader
Benefits
- Flexible design allows for single or dual excitation and emission, to address existing needs and future expansion
- User upgradable microplate reader in < 2 minutes
- High speed detection
- Excellent sensitivity and performance
- Applications at your fingertips
Features
- Array of detection cartridge capabilities
- Automatic Z-height optimization (both top and bottom read configurations)
- Fluorescence measurements no longer require you to adjust the gain
- Patented LED intensity adjustment
- Up to 1536-well format
- Temperature control
- Monochromator-based absorbance
- Filter-based fluorescence
- TUNE Cartridge available for unmatched sensitivity in wavelength tunable detection
- Custom Cartridge development available to meet your specific research needs
- SpectraDrop™ Plate protocols enabling micro volume applications measurement are included
- Seamlessly integrate with StakMax® Microplate Handling Stacker through SoftMax® Pro Software interface
Assay Kits
-
We offer optimized assay kits for use with the SpectraMax Paradigm reader.
SoftMax® Pro Microplate Data Acquistion & Analysis Software, Molecular Devices industry leading all-in-one data acquisition and analysis software comes standard with the Paradigm Platform. SpectraDrop™ Plate protocols that enable Micro Volume applications measurement are also included.
Benefits
- The most extensive library of "Ready-to-Run" application protocols to get you started faster
- Advanced calculations including non-linear fitting metrics for in-depth analysis
- Syntax Helper to simplify complex calculations
- Tools to customize reporting and exporting of data
- GxP support for 21 CFR Part 11 compliance is available

|
General Specifications |
||
|
Light source
|
High Powered LED or Flash Lamp
|
|
|
Plate formats
|
6- to 1536-well
|
|
|
Temperature range
|
4°C above ambient to 45°C
|
|
|
Uniformity
|
± 0.75°C
|
|
|
Shaking
|
Linear, Orbital
|
|
|
Endpoint measurement
|
All Modes
|
|
|
Kinetic measurement
|
All Modes
|
|
|
Well area scanning
|
All Modes
|
|
|
Wavelength scanning
|
Photometry
|
|
|
Dimensions W Ã-H Ã-D cm (in.)
|
39 (15.4) -45 (17.7) -63 (24.8)
|
|
|
Weight, without cartridges
|
45 kg (99 lbs)
|
|
|
Power source
|
100-240 VAC, 2 A, 50/60 Hz
|
|
|
Robotic compatible
|
Yes
|
|
|
Linear dynamic range
|
> 5 decades
|
|
|
Technical Specifications |
||
|
Fluorometry (FI) (Fluorescein)
|
Guaranteed*
|
Optimized
|
|
96-well (200 μL)
|
0.100 fmol
|
0.020 fmol
|
|
384-well (75 μL)
|
0.100 fmol
|
0.012 fmol
|
|
1536-well (8 μL)
|
0.030 fmol
|
0.003 fmol
|
|
Fluorescence Polarization (FP) (Fluorescein 1 nM, SD)
|
||
|
96-well (200 μL)
|
3.0 mP
|
0.5 mP
|
|
384-well (75 μL)
|
3.0 mP
|
0.5 mP
|
|
1536-well (8 μL)
|
6.0 mP
|
1.5 mP
|
|
Time Resolved Fluorescence (TRF) (Europium)
|
||
|
96-well (200 μL)
|
10.0 amol
|
2.5 amol
|
|
384-well (75 μL)
|
5.0 amol
|
1.0 amol (100 μL)
|
|
1536-well (8 μL)
|
1.5 amol
|
0.6 amol
|
|
Luminescence (Lum) (ATP-Glow)
|
||
|
96-well (200 μL)
|
0.50 fmol
|
0.30 fmol
|
|
384-well (50 μL)
|
0.50 fmol
|
0.30 fmol
|
|
1536-well (8 μL)
|
0.20 fmol
|
0.15 fmol
|
|
Photometric
|
||
|
Wavelength Range
|
230-1000 nm
|
|
|
Wavelength Selection
|
Monochromator (1.0 nm increments)
|
|
|
Wavelength Bandwidth
|
4.0 nm
|
|
|
Wavelength Accuracy
|
± 1 nm
|
|
|
Wavelength Repeatability
|
± 0.5 nm
|
|
|
Photometric Range
|
3.5 OD
|
|
|
Photometric Resolution
|
0.0001 OD
|
|
|
Photometric Accuracy
|
± (2% + 0.010 OD), 0-2 OD @ 405 nm
|
|
|
Photometric Precision
|
± (1% + 0.005 OD), 0-2 OD @ 405 nm
|
|
SpectraMax® Paradigm® features future-ready applications that can be installed and ready to use in less than two minutes. With over 20 user-installable detection cartridges available, including custom cartridges, users can easily expand their microplate reader to meet their current and future research needs.
- Fluorescence Intensity
- DNA/RNA/protein quantitation
- Endpoint qPCR
- Green fluorescent protein
- Receptor-ligand binding
- Fluorescence Polarization
- SNP genotyping
- Protein-protein interactions
- Drug receptor studies
- Absorbance
- DNA/RNA and protein purity
- ELISA
- Cell viability
- Enzyme kinetics
- Low volume applications
- Time-Resolved Fluorescence
- Enzyme Activity
- TR-FRET Eu+3 chelates
- Protein-protein interactions
- Western blot detection
- Glow Luminescence
- LIA
- Reporter gene
- cAMP
- Toxicity
- Screens
- Kinetics
SpectraMax® Paradigm Multi-Mode Microplate Reader
|
Product |
Part Number |
| SpectraMax Paradigm Multi-Mode Microplate Reader with SoftMax Pro Software | PARADIGM |
|
SpectraMax Absorbance (ABS) Detection Cartridge
|
0200-7000
|
|
SpectraMax Tunable Wavelength (TUNE) Detection Cartridge
|
0200-7050
|
|
SpectraMax Multi-mode (MULTI) Detection Cartridge
|
0200-7001
|
|
SpectraMax Fluorescence Intensity (FI) (coum-fluor) Detection Cartridge
|
0200-7002
|
|
SpectraMax Fluorescence Intensity (FI) (fluor-rhod) Detection Cartridge
|
0200-7003
|
|
SpectraMax Fluorescence Intensity (FI) (Cy3-Cy5) Detection Cartridge
|
0200-7004
|
|
SpectraMax Fluorescence Intensity (FI) (CFP-YFP) Detection Cartridge
|
0200-7005
|
|
SpectraMax Fluorescence Intensity (FI) GeneBLAzer Detection Cartridge
|
0200-7006
|
|
SpectraMax Fluorescence Intensity Dual Label (FI-DL) (MultiTox-Fluor) Detection Cartridge
|
0200-7007
|
|
SpectraMax Time Resolved Fluorescence (TRF) Detection Cartridge
|
0200-7008
|
|
SpectraMax Fluorescence Polarization (FP) (fluorescein) Detection Cartridge
|
0200-7009
|
|
SpectraMax Fluorescence Polarization (FP) (rhodamine) Detection Cartridge
|
0200-7010
|
|
SpectraMax Cisbio HTRF Detection Cartridge
|
0200-7011
|
|
SpectraMax Glow Luminescence (LUM) Detection Cartridge
|
0200-7012
|
|
SpectraMax Dual Color Luminescence (LUM) (Chroma-Glo) Detection Cartridge
|
0200-7013
|
|
SpectraMax Glow Luminescence (LUM) (96) Detection Cartridge
|
0200-7014
|
|
SpectraMax Glow Luminescence (LUM) (384) Detection Cartridge
|
0200-7015
|
|
SpectraMax Dual Color Luminescence (LUM) (BRET2TM) Detection Cartridge
|
0200-7016
|
|
SpectraMax AlphaScreen 384 STD Detection Cartridge
|
0200-7017
|
|
SpectraMax AlphaScreen 384 HTS Detection Cartridge
|
0200-7018
|
|
SpectraMax AlphaScreen 1536 HTS Detection Cartridge
|
0200-7019
|
|
Other Accessories |
|
|
Product Name
|
Part Number
|
|
SpectraDrop™ Micro-Volume Microplate Starter Kit
|
0200-6262
|
|
SpectraDrop™ Micro-Volume Microplate HTS Kit
|
0200-6267
|
|
Multi-Mode Validation Plate for SpectraMax® Paradigm® & FilterMax™ F3/F5 Systems
|
0200-7200
|
Related Videos
Brochures/Datasheets
SpectraMax Paradigm Multi-Mode Microplate Reader Brochure
Applications
- HTRF Human TNFα Assay on SpectraMax Paradigm Multi-Mode Microplate Reader
- HTRF cAMP HiRange Assay on SpectraMax Multi-Mode Microplate Readers
- IMAP Phosphodiesterase Assays on SpectraMax Multi-Mode Microplate Readers
- AlphaLISA Screen on the SpectraMax Paradigm Multi-Mode Microplate Reader Application Highlight
- Cell Migration HTS Assay on the SpectraMax Paradigm Multi-Mode Microplate Reader Application Highlight
Posters
- High Throughput Cell Based Assays for Toxicity Assessment using SpectraMax Paradigm Plate Reader Poster
- Multiplexed High Content Assays for Predictive Hepatotoxicity using Induced Pluripotent stem Cell Derived Hepatocytes Poster
- Homogeneous High Throughput Live Cell GPCR Functional and Surface Binding Assays Poster
- High-throughput Homogeous Epigenetics Assays using HTRF Technology and the SpectraMax Paradigm Microplate Detection Platform Poster
Related Webinars
- Emerging Induced Pluripotent Stem Cell Applications in Drug Discovery
- Novel In Vitro Assay Tools for Cardiac Toxicity and Discovery
Number of Citations*: 2,730
.
Artemether exhibits amoebicidal activity against Acanthamoeba castellanii through inhibition of the serine biosynthesis pathway
on a SpectraMax 179 Paradigm Multi-Mode Microplate Reader (Molecular Devices,
USA) using a fluorescence 180 excitation wavelength ...
A Novel Paradigm for the Sex Differences in Response to Ultraviolet Radiation Exposure
Exposure An Undergraduate Honors Thesis ... reaction. The brown color produced by the reaction
was read by the SpectraMax plate reader over the course of 5 min. ...
[PDF] IL-15-activated NK cells kill autologous osteoclasts via LFA-1, DNAM-1 and TRAIL, and inhibit osteoclast-mediated bone erosion in vitro.
SpectraMax Paradigm (Molecular Device). Quantification of cell viability by Presto Blue ... 535 nm
and emission at 595 nm using the SpectraMax Paradigm. TRAP staining ...
Interleukin‐15‐activated natural killer cells kill autologous osteoclasts via LFA‐1, DNAM‐1 and TRAIL, and inhibit osteoclast‐mediated bone erosion in vitro
absorbance at 405 nm with 650 nm as reference using a microplate reader SpectraMax Paradigm
(Molecular Devices, Sunnyvale, CA). Quantification of cell viability by Presto Blue. ...
基于 DNA 的比色分析法快速测定尿液中的 Hg 2+
公司);UV鄄2550 紫外分光光度计(日 本岛津公司);台式冷冻恒温摇床(太仓市实验设备厂);
PHS鄄3C 型pH 计(上海雷磁仪器厂)。 DNA 序列A (5忆鄄Biotin鄄ATCATGGACGTGCGTGTGAC ...
Microbiome structure of the fungid coral Ctenactis echinata aligns with environmental differences
products for all samples were quantified using a microplate reader (SpectraMax Paradigm,
Molecular Devices) and the Qubit Broad Range assay (Invitrogen) prior to ...
High-sensitive and high-efficient biochemical analysis method using a bionic electronic eye in combination with a smartphone-based colorimetric reader system
20 is from Carl Roth GmbH, Germany. MTPR is SpectraMax Paradigm (Molecular Devices, USA).
The smartphone is iPhone 4s and the pad is iPad 3 (Apple, USA). ...
Silver nanoparticle-embedded polymersome nanocarriers for the treatment of antibiotic-resistant infections
plate was then allowed to incubate at 37 °C inside a spectrophotometer under static conditions
(SpectraMax Paradigm, Molecular Devices, Sunnyvale, CA). ...
Improved ethanol production from xylose in the presence of acetic acid by the overexpression of the HAA1 gene in Saccharomyces cerevisiae
Growth was monitored by measuring the culture OD600 using a SpectraMax
Paradigm (Molecular Devices, Tokyo, Japan). Xylose fermentation. ...
Acetaminophen induces JNK/p38 signaling and activates the caspase-9-3-dependent cell death pathway in human mesenchymal stem cells
multi-well enzyme-linked immunosorbent assay reader (SpectraMax Paradigm
Multi-Mode Microplate Reader; Molecular Devices, Sunnyvale, CA, USA). ...
* as of June 26, 2015. Source: Google Scholar