GloMax® Discover System
Be one of the first to experience Promega's newest integrated detection system.
This ready-to-use multimode detection system includes: high-performance luminescence, fluorescence, UV-Visible absorbance, BRET and FRET, two-color filtered luminescence and kinetic measurement capabilities.
The instrument is operated by an integrated Tablet PC, which provides quick and easy navigation through the control options. Exporting your results is made seamless with a variety of options, including exporting to your local data network. The GloMax® Discover software will provide many of the required technical elements of a part 11 compliant system (user authentication and authorization, data integrity and protection, electronic signatures and audit trails) when used with the appropriate laboratory workflow.
PerformanceThe GloMax® Discover System delivers maximum flexibility with minimal user intervention. Easy-To-UseChoose from preloaded Promega protocols or customize your own. Build custom protocols using the intuitive drag-and-drop interface. Export data to a network, cloud or any drive desired. |
![]() Minimal Manual InterventionFilter paddles and automatic filter switching allow easy two-color multiplexing assays or kinetic studies. Quick read-speeds for high efficiencies in your laboratory. Compatible for 3rd party automation control. |
Superior SensitivityPlate mask (aperture control) for switching between 96-well and 384-well plates. Low cross-talk between wells gives you better, more usable results. Broad dynamic range of the instrument extends the linear range of your assay. ![]() |
QualityIQ/OQ Service available. Provides many of the required technical elements of a part 11 compliant system (user authentication and authorization, data integrity and protection, electronic signatures and audit trails) when used with the appropriate laboratory workflow.
|
| Instrument Specifications | |
| Detection Modes | Luminescence, Fluorescence Intensity, UV-Visible Absorbance, Filtered Luminescence, BRET and FRET |
| Sample Format | 6, 12, 24, 48, 96 and 384-well plates |
| Tablet PC | Windows®8 Tablet PC with USB connection to instrument |
| Read Speed | 96-well plate: less than 1 minute; 384-well plate: less than 3 minutes |
| Automation Compatibility | Hardware and software accessible to 3rd party hardware/software control, including LIMS. |
| Dimensions | 18.5in (46.9cm) width 19.5in (46.5cm) depth 10in (25.4cm) height without Tablet and PC mounted 16in (35.5cm) height with Tablet and PC mounted |
| Weight | Approximately 60lbs. (27kg) |
| Power Requirements | 120VA, 50/60 HZ |
| Warranty | 1-year parts and labor warranty included |
| Regulatory Compliance | For Research Use Only. Not for use in Diagnostic Procedures |
| Luminescence Module Specifications | |
| Detector | Top-reading, head-on photon counting photomultiplier tube (PMT) |
| Wavelength Range | 350–700nm |
| Detection Limit | 3 × 10-21 moles of luciferase |
| Linear Dynamic Range | 9 logs |
| Cross-talk | Less than 3 × 10-5 (white, 96-well plate, Corning 3912) |
| Filtered Luminescence | Built-in filter paddle |
| Fluorescence Module Specifications | |
| Detector | PIN-photodiode |
| Light Source | Wavelength-matched LED |
| Read Position | Top reading |
| Wavelengths selection | Filter module with 5 standard excitation and emission filters. Empty filter positions are available for custom excitation and emission wavelengths. |
| Wavelengths included | UV (Ex: 365nm, Em: 415-445nm) Blue (Ex: 475nm, Em: 500-550nm) Green (Ex: 525nm, Em: 580-640nm) Red (Ex: 625nm, Em: 660-720nm) AFC (Ex: 405nm, Em: 495-505nm) |
| Detection Limit | 2fmol fluorescein/200μl |
| Linear Dynamic Range | >6 logs (assay dependent) |
| UV-Visible Absorbance Module Specifications | |
| Detector | Top-reading, head-on photon counting photomultiplier tube (PMT) |
| Light Source | Xenon flash lamp |
| Spectra Range | 200-600nm |
| Filter Wheel | 9 absorbance filters included |
| Wavelengths included | 230, 260, 280, 320, 405, 450, 490, 560 and 600nm 10nm band pass |
| Detection Limit | 0.01 O.D. |
| Dynamic Range | 0-4.0 O.D. |
| Injector System Specifications | |
| Number of injectors (optional) | Two injectors |
| Dispense Volume Range | 5-200μl in 1μl increments |
| Plate Compatibility | 6, 12, 24, 48, and 96-well plates |
| Injection Speed | 20-500μl per second |
| Waste Collection Tray Volume | Approximately 50ml |
| Void Volume | 500μl |
| Shaker System Specifications | |
| Shaking Pattern | Linear or orbital patterns |
| Shaking Intensity | 100-500 cycles/minute |
| Heating System Specifications | |
| Temperature Range | Ambient to 45°C |
| PC Requirements | |
| Operating System | Windows® 8, 64 bit, with USB connection to instrument |
| RAM | 2GB |
| Disk Space | 64GB |
| Other Requirements | Microsoft.NET 4.0 Framework (full version), Microsoft Excel 2013 Professional |
-
Bioassays
- Measuring the ADCC Reporter Bioassay Complete Kit (WIL2-S) Signal on the GloMax® Discover System
-
Cell Health and Metabolism
- Measuring the Output of the CytoTox-Fluor™ Cytotoxicity Assay on the GloMax® Discover System
- Measuring the ONE-Glo + Tox Luciferase Reporter and Cell Viability Assay on the GloMax® Discover System
- Measuring Cell Viability Using the CellTiter-Glo® Cell Viability Assay and GloMax® Discover System
- Measuring P450-Glo™ Assays on the GloMax® Discover System
- Measuring Bacterial Cell Viability Using the BacTiter-Glo™ Assay and GloMax® Discover System
- Measuring Fluorescence Using the Apo-ONE® Homogeneous Caspase-3/7 Assay with the GloMax® Discover System
- Measuring Fluorescence Using the CellTiter-Blue® Cell Viability Assay with the GloMax® Discover System
- Measuring Fluorescence Using the ApoTox-Glo™ Triplex Assay With the GloMax® Discover System
- Measuring the Output of the CytoTox-Fluor™ Cytotoxicity Assay on the GloMax® Discover System
- Measuring Fluorescence Using the ApoLive-Glo™ Multiplex Assay with the GloMax® Discover System
- Measuring Absorbance Using the CellTiter 96® AQueous One Solution Cell Proliferation Assay with the GloMax® Discover System
- Measuring Luminescence of the Kinase-Glo® Luminescent Kinase Assay using the GloMax® Discover System
- Measuring Fluorescence from Cy®5 Dye using the GloMax® Discover System
- Measuring Fluorescence from Cy®3 Dye using the GloMax® Discover System
- Measuring Cell Viability Using the CellTiter-Fluor™ Cell Viability Assay and GloMax® Discover System
- Measuring Cytotoxicity Using the CytoTox-Glo™ Cytotoxicity Assay and GloMax® Discover System
-
DNA and RNA Quantification
- Measuring ssDNA Concentration Using the QuantiFluor® ssDNA System with the GloMax® Discover System
- Measuring RNA Concentration Using the QuantiFluor® RNA System with the GloMax® Discover System
- Measuring dsDNA Concentration Using the QuantiFluor® dsDNA System with the GloMax® Discover System
- Automating dsDNA Quantitation Using Promega QuantiFluor® Chemistries and Tecan Freedom EVO® System
-
Drug Discovery
- Measuring Luminescence using the GloSensor™ cAMP Assay with the GloMax® Discover System
- Measuring cAMP Levels Using the cAMP-Glo™ Assay and GloMax Discover System
-
Reporter Assays
- Measuring the ONE-Glo™ Luciferase Assay System on the GloMax® Discover System
- Measuring Filtered Luminescence of the Chroma-Glo™ Luciferase Assay System using the GloMax® Discover System
- Measuring Luminescence of the Renilla-Glo® Luciferase Assay System using the GloMax® Discover System
- Measuring Luminescence of the Steady-Glo® Luciferase Assay System using the GloMax® Discover System
- Measuring Luminescence of the Bright-Glo™ Luciferase Assay System using the GloMax® Discover System
- Measuring the Dual-Glo® Luciferase Assay on the GloMax® Discover System
- Measuring the Dual-Luciferase Reporter Assay on the GloMax® Discover
- Measuring the Luciferase Assay System on the GloMax® Discover
-
Measuring Protein Concentration
- Measuring Protein Concentration Using the BCA Protein Assay with the GloMax® Discover System
- Measuring Protein Concentration Using the 660nm Protein Assay with the GloMax® Discover System
|
GloMax® Discover System |
GM3000 |
|---|
Available Separately
| Product | Catalog # |
|---|---|
|
Light Plate, ABS/Fluor |
E6532 |
|
GloMax® Dual Injectors with Pumps |
GM3030 |
|
GloMax® Discover Luminescence Filter Paddle |
GM3011 |
|
GloMax® Discover Fluorescence Filter Paddle |
GM3012 |
|
GloMax® Discover or Explorer Installation Qualification |
SA1104 |
|
GloMax® Discover or Explorer Operational Qualification |
SA1105 |
|
GloMax® Discover or Explorer Installation and Operational Qualification |
SA1106 |
|
GloMax® Discover or Explorer Instrument Rental, 1 month |
SA1098 |
|
GloMax® Discover Standard Service Agreement |
SA4000 |
|
GloMax® Discover or Explorer Preventive Maintenance |
SA4030 |
-
GloMax Discover Video
-
Articles
- Automated cytotoxicity profiling
- Measuring Cell Viability Using the CellTiter-Fluor™ Cell Viability Assay and GloMax® Discover System
- Measuring cAMP Levels Using the cAMP-Glo™ Assay and GloMax® Discover System
- Measuring Cytotoxicity Using the CytoTox-Glo™ Cytotoxicity Assay and GloMax® Discover System
- Measuring Luminescence of the Bright-Glo™ Luciferase Assay System using the GloMax® Discover System