FilterMax F3 & F5 Multi-Mode Microplate Readers
FilterMax F3 Multi-Mode Microplate Reader
The FilterMax F3 offers a stunning set of features at an economical price. With the F3 Reader, you get visible-wavelength absorbance, top-reading fluorescence intensity, and glow luminescence modes for programmable endpoint, kinetic, multiple-wavelength linear scan and area scan measurements in 96- to 384-well plates. Easily accessible filter slides give you wavelength selection options from 340 nm to 650 nm.
FilterMax F5 Multi-Mode Microplate Reader
The FilterMax F5 gives you an even richer set of features while maintaining an economical price-to-performance ratio. With the F5 Reader, you get UV and visible absorbance, top and bottom fluorescence intensity, glow luminescence, fluorescence polarization, and time-resolved fluorescence modes, plus temperature control and linear and orbital shaking for programmable endpoint, kinetic, multiple wavelength, linear scan, and area measurements in 6- to 1536-well plates. Filter slides on the F5 Reader give you wavelength selection options from 230 nm to 750 nm.
The FilterMax™ F3 and F5 Multi-Mode Microplate Readers provide value and flexibility for a variety of applications capable of performing:
- Absorbance detection in the visible range (340 nm to 650 nm, F3) or UV and visible range (230nm to 650nm, F5)
- Fluorescence Intensity (FI) top read
- Fluorescence Intensity (FI) top read & bottom read (F5)
- Luminescence (glow)
- Fluorescence Polarization (FP) - F5
- Time-Resolved Fluorescence (TRF) - F5
- Scan measurement types: endpoint, kinetic, multiple wavelength, linear scan and area scan
- Linear and Orbital shaking
- Temperature Control
The FilterMax Series can operate as standalone instruments or can be integrated seamlessly with laboratory automation platforms, and is ideal for a broad range of applications, including drug discovery, genomics, proteomics and cell-based research. The unique patented design ensures precise performance and sensitivity across all detection modes.
Benefits
- Performance driven specifications for sensitivity, dynamic range, accuracy, precision and linearity
- Affordable multi-mode microplate reader
- Excellent price / performance ratio
Features
- 3 or 5 Modes of detection
- Automatic z-height optimization (top read) (F5 only)
- Patented LED intensity adjustment
- Up to 384-well format
- Filter based multi-mode
|
General Specifications |
||
| FilterMax F3 | FilterMax F5 | |
|
Light Source
|
High Power LEDs
|
High Power LEDs + Deuterium Lamp
|
|
Detectors
|
Silicon Photodiode + PMT
|
|
|
Filters
|
1 EX + 1 EM Filter Slides (6 filter capacity)
|
2 EX + 1 EM Filter Slides (6 filter capacity)
|
|
Plate Formats
|
96-384 well
|
6-1536 well
|
|
Measurement Methods
|
Endpoint, Kinetic, Linear Scan, Area Scan
|
|
|
Shaking
|
Linear + Orbital (3 speeds)
|
|
|
Temperature Control
|
n/a
|
Ambient +4°C to 45°C
|
|
Power/Voltage
|
100-240VAC; 50/60Hz
|
|
|
Dimensions
|
39cm W x 24cm H x 58cm L
|
|
|
Weight
|
25 kg
|
|
|
Fluorescence Intensity (FI) - Top Read
|
||
|
Wavelength Range
|
340-650nm
|
230-750nm
|
|
Detection Limit--96 well plate
|
3 fmol/200µl fluorescein
|
0.5 fmol/200µl fluorescein
|
|
Detection Limit--384 well plate
|
3 fmol/100µl fluorescein
|
0.4 fmol/100µl fluorescein
|
|
Linear Dynamic Range
|
6 decades
|
|
|
Read Time (Fly mode)
|
18sec/96well; 37sec/384well
|
|
|
Fluorescence Intensity (FI) - Bottom Read
|
||
|
Wavelength Range
|
n/a
|
300-650nm
|
|
Detection Limit--96 well plate
|
n/a
|
25 fmol/200µl fluorescein
|
|
Detection Limit--384 well plate
|
n/a
|
15 fmol/100µl fluorescein
|
|
Time-Resolved Fluorescence (TRF)
|
||
|
Wavelength Range
|
n/a
|
340-750nm
|
|
Detection Limit--96 well plate
|
n/a
|
30 amol/200µl Europium
|
|
Detection Limit--384 well plate
|
n/a
|
15 amol/100µl Europium
|
|
Linear Dynamic Range
|
n/a
|
5 decades
|
|
Read Time (1sec integration)
|
n/a
|
180sec/96well; 690sec/384well
|
|
Fluorescence Polarization (FP)
|
||
|
Wavelength Range
|
n/a
|
300-750nm
|
|
Detection Limit--96 well plate
|
n/a
|
3 mP at 10nM Fluorescein
|
|
Detection Limit--384 well plate
|
n/a
|
4 mP at 10nM Fluorescein
|
|
Read Time (Fly mode)
|
n/a
|
38sec/96well; 79sec/384well
|
|
Luminescence (LUM) - Glow
|
||
|
Wavelength Range
|
400-650nm
|
400-750nm
|
|
Detection Limit--96 well plate
|
2 fmol ATP
|
|
|
Linear Dynamic Range
|
6 decades
|
|
|
Read Time (Fly mode)
|
18sec/96well; 37sec/384well
|
|
|
Absorbance (Abs)
|
||
|
Wavelength Range
|
340-650nm
|
230-650nm
|
|
Indication Range
|
0-3.5 OD
|
|
|
Accuracy
|
<+1%+10mOD at 2 OD
|
|
|
Reproducibility
|
<+0.5% and +0.005 OD at 2 OD
|
|
|
Read Time
|
18sec/96well; 37sec/384well
|
|
|
Operating System
|
||
|
Item
|
Minimum
|
Recommended |
| Processor | Single-core, 2 GHz or faster | Quad core or faster |
|
Operating System
|
Window 7, 32-bit or 64-bit (x86 or x64) and .NET Framework 4.0 (.NET Framework is installed automatically by the SoftMax Pro Software installer if necessary)
|
Windows 7, 32-bit or 64-bit (x86 or x64), or Windows 8, 32-bit or 64-bit (x86 or x64) |
| Data Connection | RS-232 serial port or USB 2.0 port (depending on the instrument) | USB 2.0 ports; For those that require an RS-232 serial port, you can use a USB 2.0 port with a Keyspan, USB-to-serial adapter. Keyspan USB-to-serial adapters have been field tested and approved by Molecular Devices. |
| Memory | 2 GB RAM | 4GB RAM; If running on a virtual machine, Molecular Devices recommends a minimum of 6 GB RAM. For automation, Molecular Devices recommends a minimum of 8 GB RAM. |
| Hard Disk | 500 MB of available space | 1 GB of available space or more |
| Graphics Display | Graphics display adapter 1024 x 768 or higher resolution display | 32-bit graphics display with 265 MB video RAM; 1280 x 1024 or higher resolution display |
| Software Installation and Activation | CD/DVD drive; Internet connection or external USB drive | CD/DVD drive; Internet connection |
From basic research to drug discovery, the FilterMax series cover a range of applications at an affordable price without sacrificing performance of your multi-mode microplate reader.
Representative Applications
- Apoptosis
- Cell proliferation, viability, cytotoxicity
- ELISA
- Endotoxin tests, agglutination assays
- Enzyme activity and kinetic assays
- Genotyping
- GPCRs
- Molecular interactions
- Nucleic acid and protein quantitation
- Proliferation assays
- Reporter gene assays with fluorescent proteins (GFP)
|
Product |
Product Number |
| FilterMax F3 Microplate Reader | F3 |
| FilterMax F5 Microplate Reader | F5 |
|
FilterMax FLUORESCENCE EXCITATION FILTER 360NM BW 35NM
|
6590-0042
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 485NM BW 20NM
|
6590-0043
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 535NM BW 25NM
|
6590-0044
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 430NM BW 35NM
|
6590-0045
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 590NM BW 20NM
|
6590-0046
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 320NM BW 25NM
|
6590-0047
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 405 NM BW 30NM
|
6590-0048
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 465NM BW 35NM
|
6590-0049
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 500NM BW 25NM
|
6590-0050
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 518NM BW 26NM
|
6590-0051
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 525 NM BW 45NM
|
6590-0052
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 540NM BW 25NM
|
6590-0053
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 550NM BW 10 NM
|
6590-0054
|
|
FilterMax FLUORESCENCE EXCITATION FILTER 585NM BW 10NM
|
6590-0055
|
|
Description
|
|
|
FilterMax FLUORESCENCE EMISSION FILTER 465NM BW 35NM
|
6590-0056 |
|
FilterMax FLUORESCENCE EMISSION FILTER 535NM BW 25NM
|
6590-0057 |
|
FilterMax FLUORESCENCE EMISSION FILTER 595NM BW 35NM
|
6590-0058 |
|
FilterMax FLUORESCENCE EMISSION FILTER 625NM BW 35NM
|
6590-0059 |
|
FilterMax FLUORESCENCE EMISSION FILTER 430NM BW 35NM
|
6590-0060 |
|
FilterMax FLUORESCENCE EMISSION FILTER 650NM BW 40NM
|
6590-0061 |
|
FilterMax FLUORESCENCE EMISSION FILTER 485NM BW 20NM
|
6590-0062 |
|
FilterMax FLUORESCENCE EMISSION FILTER 500 NM BW 25NM
|
6590-0063 |
|
FilterMax FLUORESCENCE EMISSION FILTER 550NM BW 10NM
|
6590-0064 |
|
FilterMax FLUORESCENCE EMISSION FILTER 574 NM BW 25NM
|
6590-0065 |
|
FilterMax FLUORESCENCE EMISSION FILTER 585NM BW 10NM
|
6590-0066 |
|
FilterMax FLUORESCENCE EMISSION FILTER 635NM BW 35NM
|
6590-0067 |
|
FilterMax FLUORESCENCE EMISSION FILTER 660NM BW 32NM
|
6590-0068 |
|
FilterMax FLUORESCENCE EMISSION FILTER 668NM BW 12NM
|
6590-0069 |
|
FilterMax FLUORESCENCE EMISSION FILTER 670NM BW 40NM
|
6590-0070 |
|
Product Name
|
Product Number |
| FilterMax FLUORESCENCE POLARIZATION (FP) Excitation Filter Visible | 6590-0071 |
|
FilterMax FLUORESCENCE POLARIZATION (FP) Emission Filter Visible (QTY 2)
|
6590-0072
|
|
Product Name
|
Product Number |
|
FilterMax TIME RESOLVED FLUORESCENCE (TRF) Excitation Filter 370NM BW80 NM
|
6590-0073
|
|
Product Name
|
Product Number |
| FilterMax ABSORBANCE FILETER 280NM BW 5,5NM | 6590-002 |
| FilterMax ABSORBANCE FILTER 260NM BW 5,5NM | 6590-001 |
|
FilterMax ABSORBANCE FILTER 320NM BW 5,5NM
|
6590-0003
|
|
FilterMax ABSORBANCE FILTER 420NM BW 8NM
|
6590-0004
|
|
FilterMax ABSORBANCE FILTER 450NM BW 8NM
|
6590-0005
|
|
FilterMax ABSORBANCE FILTER 465NM BW 8NM
|
6590-0006
|
|
FilterMax ABSORBANCE FILTER 470NM BW 8NM
|
6590-0007
|
|
FilterMax ABSORBANCE FILTER 480NM BW 8NM
|
6590-0008
|
|
FilterMax ABSORBANCE FILTER 490NM BW 8NM
|
6590-0009
|
|
FilterMax ABSORBANCE FILTER 492NM BW 8NM
|
6590-0010
|
|
FilterMax ABSORBANCE FILTER 510NM BW 8NM
|
6590-0011
|
|
FilterMax ABSORBANCE FILTER 515NM BW 8NM
|
6590-0012
|
|
FilterMax ABSORBANCE FILTER 520NM BW 8NM
|
6590-0013
|
|
FilterMax ABSORBANCE FILTER 532NM BW 8NM
|
6590-0014
|
|
FilterMax ABSORBANCE FILTER 540NM BW 8NM
|
6590-0015
|
|
FilterMax ABSORBANCE FILTER 548NM BW 8NM
|
6590-0016
|
|
FilterMax ABSORBANCE FILTER 550NM BW 8NM
|
6590-0017
|
|
FilterMax ABSORBANCE FILTER 560NM BW 8NM
|
6590-0018
|
|
FilterMax ABSORBANCE FILTER 562NM BW 8NM
|
6590-0019
|
|
FilterMax ABSORBANCE FILTER 570NM BW 8NM
|
6590-0020
|
|
FilterMax ABSORBANCE FILTER 575NM BW 8NM
|
6590-0021
|
|
FilterMax ABSORBANCE FILTER 580NM BW 8NM
|
6590-0022
|
|
FilterMax ABSORBANCE FILTER 590NM BW 8NM
|
6590-0023
|
|
FilterMax ABSORBANCE FILTER 595NM BW 8NM
|
6590-0024
|
|
FilterMax ABSORBANCE FILTER 600NM BW 8NM
|
6590-0025
|
|
FilterMax ABSORBANCE FILTER 610NM BW 8NM
|
6590-0026
|
|
FilterMax ABSORBANCE FILTER 620NM BW 8NM
|
6590-0027
|
|
FilterMax ABSORBANCE FILTER 630NM BW 8NM
|
6590-0028
|
|
FilterMax ABSORBANCE FILTER 640NM BW 8NM
|
6590-0029
|
|
FilterMax ABSORBANCE FILTER 645NM BW 8NM
|
6590-0030
|
|
FilterMax ABSORBANCE FILTER 650NM BW 8NM
|
6590-0031
|
|
FilterMax ABSORBANCE FILTER 340NM BW 10NM
|
6590-0032
|
|
FilterMax ABSORBANCE FILTER 350NM BW 10NM
|
6590-0033
|
|
FilterMax ABSORBANCE FILTER 360NM BW 10NM
|
6590-0034
|
|
FilterMax ABSORBANCE FILTER 370NM BW 10NM
|
6590-0035
|
|
FilterMax ABSORBANCE FILTER 380NM BW 10NM
|
6590-0036
|
|
FilterMax ABSORBANCE FILTER 405NM BW 10NM
|
6590-0037
|
|
FilterMax ABSORBANCE FILTER 414NM BW 10NM
|
6590-0038
|
|
FilterMax ABSORBANCE FILTER 260NM BW 12NM
|
6590-0039
|
|
FilterMax ABSORBANCE FILTER 280NM BW 12NM
|
6590-0040
|
|
FilterMax ABSORBANCE FILTER 320NM BW 12NM
|
6590-0041
|
FilterMax F3/F5 brochure
Number of Citations*: 126
.
Identification of phenolics in litchi and evaluation of anticancer cell proliferation activity and intracellular antioxidant activity
min for 35 cycles using a multimode microplate reader (Filter Max F5, Molecular Devices, USA)
with an excitation wavelength of 485 nm and an emission wavelength of 538 nm. ...
The NADPH oxidase inhibitor DPI can abolish hypoxia-induced apoptosis of human kidney proximal tubular epithelial cells through Bcl2 up-regulation via ERK …
of the cell cultures was measured at a wavelength of 450 nm using a Molecular Devices Filter
MAX F5 microplate reader (Molecular Devices, Sunnyvale, CA, USA). ...
[HTML] Rapid and Liquid-Based Selection of Genetic Switches Using Nucleoside Kinase Fused with Aminoglycoside Phosphotransferase
measured using a fluorescence microtiter-plate reader (FilterMax F5, Molecular Devices,
Sunnyvale, CA, USA) with excitation at 485 nm and emission at 535 nm. ...