MET ONE 6000
Remote Air Particle Counter | Benefits of selecting the MET ONE 6000
Industry leading particle counting on-line reliability
ISO 21501 compliant with built-in flow sensor for CFR21 data accuracy and reliability
Flexible for all your remote air particle counter applications
Flexible particle count size in 0.3um or 0.5um sensitivity at 0.1cfm or 1.0cfm flow rates
Industry leading quality and reliability
Long life laser diode for guaranteed continuous monitoring
Easy to integrate with any facility monitoring system
Open architecture design to communicate seamlessly with your system Multiple communication options: Pulse, Serial Modbus, Ethernet, Wireless and Analog
Faster trouble shooting and reduced downtime
MET ONE 6000 remote air particle counters can be diagnosed for flow, sensor, or communication failures to provide advanced notification of hardware problems Count alarm and alerts enable visual notification via built-in status lights
Easy installation options – reducing cost
Reduce initial installation cost with MET ONE 6000 remote air particle counter’s integrated multi-parameter measurements. Optional relative humidity and temperature probe integrates RH/T data with particle count data in same data stream
| Number of Size Channels | Standard 2 or Optional 4 (pulse units have 2 channels only) |
| Light Source | Long Life Laser™ diode |
| Weight | 0.68 kg (1.5 lb) |
| Dimensions | 13.56 w x 8.13 d x 10.87 h cm (5.34 x 3.20 x 4.28 inches) |
| Enclosure | 304 stainless steel |
| Power Requirements | 9 to 28 VDC |
| Power Consumption | Serial and pulse unit: 3.3 W maximum; Ethernet unit: 4.3 W maximum |
| Operating Temperature | 10 to 32 °C (50 to 90 °F), 5 to 95% relative humidity, non-condensing |
| Storage Temperature | -40 to 70 °C (-40 to 158 °F), 5 to 98% relative humidity, non-condensing |
| Signal Output Options | Pulse, Analog 4–20 mA, Serial RS-232, Serial RS-485 with Modbus RTU or FXB communication protocol, Ethernet with TCP/IP protocol |
| Vacuum Requirements | At least 40.6 cm (16 inches) Hg |
| Flow Control | Through critical orifice |
| Coincidence Loss | Model 6002/6003: 5% at 2,000,000 particles/ft3, (70,600,000 particles/m3), Model 6015: (except Pulse) 5% at 400, 000 particle/ft3, (14,000,000 particles/m3) |
| False Count Rate | One or less in five minutes |
| Status Indicator | Multi-colored LED for normal status, count alarm, count alert, sensor failure, flow failure or communication failure |
ISO 14644 Compliance
- ISO21501 compliance ensures you are proactively compliant to the next revision of ISO14644
Aseptic Cleanroom Manufacturing
- The MET ONE 6000 remote air particle counter is specifically designed to manage all aseptic fill cleanroom fixed location applications
Semiconductor Cleanroom Environments
- Industry’s most accurate particle counting fully complies to ISO21501 calibration standards, the MET ONE 6000 remote air particle counter assures increase yield
Flat Panel Cleanroom Environments
- Increase yield and eliminate contamination concerns in your flat panel production area with the MET ONE 6000 remote air particle counter
Hard Disk Drive Cleanroom Environments
- The MET ONE 6000 remote air particle counter provides low cost of ownership price-per-point particle counting with industry leading high quality
Accessories included with the MET ONE 6000 remote particle counter:
| Part Number | Description |
|---|---|
| 490-200-0001 | Antenna for Wi-Fi counter (based on unit configuration) |
| 2088343-01,-02,-03,-04 | Ship kit, standard (includes DIN rail kit, Phoenix terminal, isokinetic probe) |
Optional accessories:
| Part Number | Description |
|---|---|
| 2088517 | Bracket, to mount RH/temperature probe |
| 2088480 | Bracket, to mount external LED light stack with isokinetic probe |
| 2088482 | Bracket, wall, for external LED light stack |
| 2082644-3 | Bracket, wall, for isokinetic probe |
| 2088397-01 | Cable, for external stainless steel LED light stack, 3 m with connector |
| 460-400-1010 | Cable, for external plastic LED light stack, 3 m with mini-DIN M/F connector |
| 2088379-01 | Cable, service port (8-pin DIN to 9-pin serial) |
| 2088518-01 | Cable assembly with RJ45 adapter |
| 410-170-0395 | Connector, 5-pin with clam shell, terminal strip |
| 410-500-4372 | Connector, 5-pin with clam shell, backshell |
| 410-170-0447 | Connector, 10-pin with clam shell, terminal strip |
| 410-500-4424 | Connector, 10-pin with clam shell, backshell |
| 203813-3 | Filter, zero counting, 1 cfm ¼ in. tube |
| 2088667 | Filter, zero counting, 0.1 cfm 1/8 in. tube |
| 2088396-01 | Light stack, stainless steel, external LED |
| 2088559-01 | Light stack, plastic, external LED |
| 2088378-01 | Mounting kit, DIN rail |
| 2088525 | Mounting kit, wall plate |
| 2088601-02,-03,-15 | Option, 4-channel setting |
| 2088600-232, -485, -PLS | Option, I/O for Met One 6000 serial unit |
| 230-300-0001 | Power supply unit, 24 VDC, 5.0 A, universal input for FMS |
| 2080416-1 | Probe, isokinetic 0.1 cfm |
| 2082646-2 | Probe, isokinetic 1.0 cfm |
| 2080999-1,-2,-5 or -6 | Probe, extended—vertical wall mount, 0.1 cfm |
| 2080999-3, -4 | Probe, extended—vertical wall mount, 1.0 cfm |
| 2080999-7, -8,-11,-12 | Probe, extended—vertical wall mount with bracket for indicator light stack, 0.1 cfm |
| 2080999-9, -10 | Probe, extended—vertical wall mount with bracket for indicator light stack, 1.0 cfm |
| 2082366-1 | Probe mount—ceiling, 90 degree (1.0 cfm only) |
| 2088373-01 | RH (relative humidity)/temperature probe with cable |
| 2088516-01 | Setup kit, configuration (includes service port cable) |
| 2088343-01,-02,-03,-04 | Ship kit, standard (includes DIN rail kit, Phoenix terminal, isokinetic probe) |
| 960200 | Tubing, ¼-inch ID |
| 960024 | Tubing, 1/8-inch ID |