HIAC 9703+
Liquid Particle Counter | Benefits of selecting the HIAC 9703+
Industry’s smallest samples
Perform a full suite of tests with just 1mL of product
Manages all your application needs
Handle a full range of sample volumes from1 mL to >1000 mL Pre-configured USP, EP, JP, and KP test routines
Eliminate uncertainty from data
Alarm notification when bubbles and/or sensor contamination has impacted particle counting results
Secure sample handling
Small vial holder ensures no expensive sample gets wasted
Easily configurable for maximum flexibility
Select a preferred flow rate and utilize interchangeable sensors from 0.5 to 600µm particle size detection
Avoid costly down time
On-site service significantly reduces down time - no shipping of your unit required. Automated notification when your unit is in need of routine service
Eliminate anxiety of data loss
Data loss recovery feature protects the results in the event of a power interruption or loss. Automatic database backup to a secure network location via PharmSpec
HIAC Particle Counting Instrument Validation Services
SOP assistance and IQ/OQ validation services Utilize HIAC expertise to get your system out of the box and commissioned
HIAC 9703+ Liquid Particle Counter
| Weight | 10.7 kg (23.6 lbs) |
| Dimensions | 343mm W X 337mm D X 482mm H (13.5 X 13.3 X 19.0 inches) |
| Operating Temperature | 5 to 40°C (40 to 104°F) 0 to 80% relative humidity, non-condensing |
| Sample Temperature | 5 to 40°C (40 to 104°F) |
| Power | 100/230 VAC, 50/60 Hz, 67 W at 115/230 VAC |
| Viscosity Limit | |
| Sample Bottle Clearance | 153 mm (6.02 inches) |
| Volume Accuracy | > 95% |
| Flow Rate Accuracy | > 95% |
| Sample Flow Rate | 10 to 100 ml/min; Actual flow rate for the system is determined by the sensor’s flow rate with step-by-step instructions and Pass/Fail results. |
| Tare Volumes for Probes | 0.091 ml for 81 L x 1.2 mm I.D (3.2 x 0.047 inches) 0.172 ml for 154 L x 1.2 mm I.D. (6.1 x 0.047 inches) 1.57 ml for 140 L x 6.35 mm I.D. (5.5 x 0.25 inches) – large bore |
PharmSpec 3 Software - for use with the HIAC 9703+ Liquid Particle Counter
| Processor | Pentium® 1.0 GHz |
| Operating System | Windows® XP with Service Pack 3 or later Windows Vista® with Service Pack 2 or later Windows 7 (32 bit) |
| Memory | 512 MB of RAM |
| Hard Disk | 2 GB of available hard-disk space |
| Drives | CD drive, DVD drive, USB port or network connection is required for installation |
| Display | Super VGA video adapter and monitor,1024 x 768 or higher resolution |
| Power Supply | Uninterrupted power supply (UPS) |
| Removable Drive | Removable drive for backing up data, such as a recordable CD or a network server that can back up the computer hard drive |
| Printer | Color printer capable of printing at 300 dpi |
| COM Port | USB port to connect to the particle counting system |
| Software | Internet Explorer 6.0 or higher and Microsoft® Excel®, Word® or Adobe® Acrobat® (to access PharmSpec reports) |
Applications:
USP Particulate Matter in Injections and Parenteral Infustions
- HIAC 9703+ Liquid Particle Counting System
- HIAC PharmSpec Liquid Particle Counting Software
- HIAC HRLD Liquid Particle Counting Sensors
- HIAC MC05 Liquid Particle Counting Sensor (sub-micron)
Regulatory Links:
- USP
- USP
- USP
USP Particulate Matter in Ophthalmic Solutions:
- HIAC 9703+ Liquid Particle Counting System
- HIAC PharmSpec Liquid Particle Counting Software
- HIAC HRLD Liquid Particle Counting Sensors
- HIAC MC05 Liquid Particle Counting Sensor (sub-micron)
USP Pharmaceutical Compounding - Sterile Preparations
- HIAC 9703+ Liquid Particle Counting System
- HIAC PharmSpec Liquid Particle Counting Software
- HIAC HRLD Liquid Particle Counting Sensors
- HIAC MC05 Liquid Particle Counting Sensor (sub-micron)
Liquid Particle Counting Release Test Standards:
- USP Particulate Matter in Injections and Parenteral Infusions
- USP Particulate Matter in Ophthalmic Solutions
- USP Pharmaceutical Compounding - Sterile Preparations
- Parenteral Drug Association
- European Directorate for the Quality of Medicines & Healthcare
Included Accessories with the HIAC 9703+ Liquid Particle Counter
| Part Number | Description |
|---|---|
| 90450001 | Vial sampler probe, 0.063” O.D. X 5.88” long stainless steel |
| 90620008 | Vial sampler probe, 0.25” O.D. x 5.88” long Stainless steel |
| 90630002 | Nut, for securing vial sampler probes to the sensor |
| 089208-01 | Drain tube assembly |
| 230-300-7052 | Power Supply, +24 VDC @ 3A |
| VP623500 | Universal EU Power Cord, AC, 6’ long, 230V |
| VP623501 | US Power Cord, AC, 6' long, 115V |
| 460-400-4799 | USB Cable 2.0 Pro Series hi-speed |
| 600-100-0003 | Magnetic Stirrer Bar, Teflon coated |
| 690-300-4808 | Syringe, 10mL XLP style |
| 808-010-200 | O-ring Viton, 2-010 for use on sensor fittings, 2 each |
| 680-000-0030 | Allen Wrench, 1.5mm |
| DOC026.97.80097 | 9703+ User’s manual |
Optional Accessories for the HIAC 9703+ Liquid Particle Counter
| Part Number | Description |
|---|---|
| 2089006-01 | Small vial sampling kit Includes: P/N 2089099-01, Vial clamp assembly P/N 90450004, Vial sampler probe 0.063” x 3” long P/N 690-300-4805, Syringe, 1 mL XLP style |
| 2089099-01 | Vial clamp assembly |
| 90450004 | Vial sampler probe 0.063” x 3” long |
| 690-300-4805 | Syringe, 1 mL XLP style |
| 690-300-4809 | Syringe, 25 mL XLP style |
| FACTORY_CAL_USP_PRE | USP Factory calibration per USP |
| 2089290-01 | HRLD Sensor Holder assembly |
| 2089291-01 | MC-05 Sensor Holder assembly |
| 2089179-01 | Cable Assembly, HRLD to 9703 Plus |